Yale SmartHome Alarm series Spezifikationen

Stöbern Sie online oder laden Sie Spezifikationen nach Sicherheitszugriffskontrollsysteme Yale SmartHome Alarm series herunter. Yale SmartHome Alarm series Specifications Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 32
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Easy Fit Touch Screen
alarm system (EF-Panel)
Installation · Programming · Operating
Keep this manual safe for reference and future maintenance
Introduction Contents
Thank you for choosing the Yale Wireless Alarm System.
This simple to install system has been designed with the
user in mind.
All the components are self contained and no connections
are needed between the units. There is no need to
damage the home decor, lift carpets or run cables.
You can install up to 20 devices in this system. As well as
extra door/window contacts, PIRs and smoke detectors,
you can add keyfob remote controls and keypads for
added control convenience.
There is no need to wire into the mains supply or seek
the services of a qualified electrician. The control unit is
powered by a plug top supply and all other components
are powered by battery (all batteries included).
Batteries will operate for 2 years or more before they need
changing. Regular testing and battery changes (when
notified by the system) will ensure reliability and peace of
mind.
The security detectors, control panel and external siren
are ‘tamper’ protected. Any unauthorised tampering with
these items will result in an alarm. This feature can be
turned off by the user when a battery change is required.
Display extreme caution when using ladders or steps,
please follow manufacturer’s instructions.
Be careful when using hand and power tools and follow
the manufacturer’s guidelines when using them. Take care
that the correct tools are used. Wear goggles or protective
clothing where required.
The external Siren is extremely loud, please ensure you
replace the cover and retreat to a safe distance before
testing.
The dialling facilities must only be used with persons who
have consented to being contacted by the system.
The system is not to be used to make 999 emergency
calls directly. Yale do not hold responsibility for any actions
taken by emergency services for incorrect use of the
dialling facility.
Special Notes on Compatibility:
This alarm system is NOT compatible with SmartHome
Alarm, HSA6000 series and HSA3000 series accessories.
Please note the prefix “EF-” on the front of the part
number to indicate compatibility.
Information and illustrations are subject to change within this
document. Yale reserves the right to alter the specification and
product design at anytime without notice. Yale® is a registered
trademark. © 2012 ASSA ABLOY. All rights reserved.
Contents
1 Location planning 2
2 Unpack all the parts 4
3 First Time Easy Install 6
4 Mounting alarm devices 8
5 Control Panel Menu System in Detail 11
6 Using the System 17
Adding and using Accessories 20
Changing the batteries 22
Troubleshooting 24
Sensor response table 27
Specifications 28
Recommended Installation Sequence
We recommend you follow the simple install
sequence, headings numbered 1-6.
Seitenansicht 0
1 2 3 4 5 6 ... 31 32

Inhaltsverzeichnis

Seite 1 - Easy Fit Touch Screen

Easy Fit Touch Screen alarm system (EF-Panel) Installation · Programming · OperatingKeep this manual safe for reference and future maintenanceIntroduc

Seite 2 - Location planning

10About your alarm system (default settings)To set up more telephone numbers (maximum 3 in total), please see Chapter 5, Tel. Settings.iYou can record

Seite 3 - Text Display

11Control Panel Menu System in DetailEntering Programming ModeThe programming mode is for you to configure the system, and make any changes to the pre-

Seite 4 - Unpack all the parts

12If you press any test/learn button on any learnt-in sensor (confirm by pressing 3), these sensors will be ignored during the Home Arm mode. Repeat th

Seite 5 - Learn/Test

13•A24Hourdoorcontactisactiveallofthetimeand does not have to be armed or disarmed, if triggered a burglar alarm will be activated immedia

Seite 6 - First Time Easy Set-up

14LogThe alarm log memorises the last 30 system events including:· All alarm events with device names and type· All fault warning events· All arming a

Seite 7 - (Upon selecting Exit setup)

15second increments.•30secondsisthefactorydefault.Entry SoundThe control unit will beep during the entry delay period as an entry warning, you c

Seite 8 - Control Unit Mounting

16•Warningonisthefactorydefault.TimeThe control unit uses a 24 hour clock. The time is set by using the pq keys and confirmed by pressing the 3

Seite 9 - Mounting the Smoke Detector

17Using the SystemThe PIRs have a built-in sleep timer to savebattery power. If there is no movement in frontof the PIRs for 1 minute, the PIRs will b

Seite 10

18or away entry are triggered, the alarm will be activated immediately.Stop the Alarm and Alarm DisplayDuring an alarm, the control panel and outside

Seite 11 - Press test on

19 Disabling the system tamperBefore mounting it is important to disable the siren and system tamper to avoid the siren sounding an alarm.1 Press

Seite 12 - Zone Type List

2Y alealeY1236547890aleYaleYText DisplayLocation planningHome and Away Mode PlanningThe home arming mode allows the premises to be part armed so that

Seite 13 - Program Siren

20Adding and using AccessoriesPreparationSee section 2 for battery insertion, activation and part identification. See also section 1 and section 4 for

Seite 14 - Adv. Settings

21Using your keypad•ThekeypadcanbeusedtoAwayArmandHomeArm the system using the buttons as shown.•Thesystemisdisarmedbypressingthedi

Seite 15

22Changing the BatteriesControl unit low battery IndicationThe control unit will display all device low battery conditions with the exception of the s

Seite 16 - Tel. Settings

23Keyfob battery changeWhen the battery is low the LED will glow dimly when any key is pressed. The battery is changed as follows:1 Using a coin turn

Seite 17 - Using the System

24TroubleshootingSirenSiren does not respond to arming or disarming•Sirenbatteriesarecompletelyexhausted. Check siren batteries by removing sir

Seite 18 - Stop the Alarm and Alarm

25_____________________________________________RED triangle LED illuminates and warning beeps (every 30 seconds if enabled)•Thereisafaultconditio

Seite 19 - Enabling the system tamper

265 Press the P key.6 All programmed parameters are reset to factory default setting. All learnt sensors will be kept.7 If more than 17 incorrect keys

Seite 20 - Using your keyfob

27Alarm sensor response tableDisarm Away Arm Home Arm Exit Away Arm EntryHome Arm EntryBurglar No action Instant Burglar alarmInstant Burglar alarmNo

Seite 21 - Using your Help Button

28SpecificationsAll devices Environmental conditions -10°C to 40°C, relative humidity 70% non-condensing for all units except the external siren. Siren

Seite 22 - Changing the Batteries

2917Model: HSA3400HSA3020HSA3060HSA3010HSA3050HSA3045HSA3080HSA3030HSA3070ASSA ABLOY Ltd.School StreetWillenhallWest MidlandsEnglandWV13 3PWEF-KIT1EF-

Seite 23 - Smoke detector battery change

3Y alealeY1236547890aleYaleYText DisplayKeyfob remote control accessoryCan be used inside or outside the property and can be kept on your keyring.Smok

Seite 24 - Troubleshooting

30Installation Notes:

Seite 26

E2 09\12THE YALE BRAND, with its unparalleled global reach and range of products, reassures more people in more countries than any other consumer lock

Seite 27 - Alarm sensor response table

4Unpack all the partsControl unitUnpack the kit content on a table. Remove the mounting plate (if fitted) from the control unit by sliding plate downwa

Seite 28 - Specifications

5Door/window contacts 1 Pull out the battery saver tab on the side to activate the battery.aleYLearn/TestbuttonLEDGap no more than 10mmMagnetSensorKey

Seite 29 - On behalf of ASSA ABLOY Ltd

6First Time Easy Set-up  •Anyomissionsormistakescanberectied  later. Once the first time install has been successfully complet

Seite 30 - Installation Notes:

7Next, the screen will display: .Exit setup Repeat Setup Upon selecting “Exit Setup”, you will now be prompted with: mount devices, see Ma

Seite 31

8Post Installation/Mounting Devices4Note: Tamper is disabled during initial set-up. For details on disabling tamper see Section 6Control Unit Mounting

Seite 32 - Statement

9 Wall fixingknockouts x2Corner fixingknockouts x4Battery tab2 Drill holes into the wall using the knockout holes on the base as a template.3 Fit wa

Kommentare zu diesen Handbüchern

Keine Kommentare