If you press any test/learn button on any learnt-in
sensor (confirm by pressing 3), these sensors will be
ignored during the Home Arm mode.
Repeat this step to ignore additional sensors.
Devices
Select ‘Devices’ in the main programming menu to
add or remove a device. From here you will be able
to view a list of all the devices being installed and
you can add or delete devices. The following items
can be selected.
· Add Device
· Edit Devices
· Remove Device
· Program Siren
Add Devices
1 To learn-in a new device select ‘Add Device’
then press 3, a “push Button on Device to Add”
message will be shown.
2 Press the learn button on the device within 30
seconds (see Chapter 2 for location).
3 If a signal is detected, the screen will show the
type of device found.The upper right corner will
show the radio signal strength ranging from 1 to 9
(strongest). Relocate the sensor if this is below 5
(unstable).
•Devicesarelabeledbythefollowingcodeswithin
the control unit:
· Door Contact DC
· PIR Sensor IR
· Smoke Sensor SD
· Remote Keyfob RC
· External Siren BX
· Remote Keypad KP
· Help Button FP (Fix-Panic)
•Whenasensorisaddedtothesystemfor
a second time, an error “Already in System”
message will be briefly displayed and the control
unit will wait for another learn-in signal.
4 Press 3 to confirm the device type.
5 The following zone types will need setting for door
contacts and PIRs:
· Burglar
· Home Omit
· Entry
· Away Entry
· 24 Hour (DC only)
The following devices have a fixed emergency
zone type:
· Smoke Detector
· Remote Controller emergency Button
· Help Button
· Remote Keypad dual emergency buttons
· Control Unit dual key emergency (1 and 3) keys
Zone Type List
Burglar
•Whenthesystemisinhomeorawayarmedmode
and a burglar device is triggered, a burglar alarm
will be activated immediately.
•Adevicesettoburglarwillnottriggeranalarm
during entry or exit delay periods.
Home Omit
•Ahomeomitdevicewillbeignoredwhenthe
system is home armed.
•Ahomeomitdevicewillgiveaburglaralarmwhen
the system is away armed.
Entry
•Ifanentrydeviceistriggeredwhenthesystemis
either away or home armed, it will start an entry
delay period to give enough time to disarm the
system.
•Ifthedelayperiodexpireswithoutbeingdisarmed,
the control panel will respond with a burglar alarm.
•Ifthedevicehasbeensettoentryandtriggered
when the system is in disarmed mode, the control
unit will make a ‘ding-dong’ door chime sound if
the door chime feature is enabled.
Away Entry
•Ifanawayentrydeviceistriggeredwhenthe
system is in armed mode, the control unit will
start an entry delay period to give enough time to
disarm the system.
•Ifthedelayperiodexpireswithoutbeingdisarmed,
the control panel will respond with a burglar alarm.
•Anawayentrydeviceisignoredwhenhome
armed.
•Thedevicewillnotgivea“dingdong”chimesound
when door chime is selected.
24 Hour
•Thedoorcontactistheonlydevicethathasthis
zone type, the PIR does not.