Yale SmartHome Alarm series Spezifikationen Seite 17

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 20
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 16
17
Troubleshooting
Siren
Siren does not respond to arming or disarming
•Sirenbatteriesarecompletelyexhausted.
Check siren batteries by removing siren cover, if
there is no tamper alarm when removed, replace
batteries with new alkaline equivalents.
•Sirennotlearnt-in.Ifsirenproducesatamper
alarm when the cover is removed and siren is OK,
learn-in the siren.
•Sirenoutofrange.
Siren produces a 3 second alarm when
disarmed
•Therehasbeenapreviousalarmandtheremight
be an intruder still in the premises.
Siren produces a series of pips when armed or
disarmed
•Thesirenhaslowbatteries.Checkthatthe
siren produces a series of pips when arming
and disarming, indicating low batteries. Change
batteries with new alkaline replacements.
•Thesirentamperswitchhasbeendisturbed.
Check that the siren produces a series of pips only
when arming, indicating a tamper fault. Check that
the siren cover is firmly secured and the tamper
switch plunger is in contact with the wall. If not use
suitable packing material to fill gap.
Siren produces an interrupted tone when
sounding an alarm
•Thesirenhaslowbatteries.Changebatterieswith
new alkaline replacements.
_____________________________________________
PIR
PIR does not respond to movement
•PreviousmovementhastriggeredthePIRsleep
timer and is preventing subsequent movement
detection. Arm system and vacate protected room
for at least 1.5 minutes before testing.
PIR is slow to respond
•Thisisnormal,thePIRhassophisticatedfalse
alarm filtering that will filter out random fluctuations
and responds to genuine movement across field of
view, it is less sensitive walking directly towards it.
PIR gives false alarms
•Checkpetshavenoaccesstoprotectedarea.
•CheckthatPIRisnotpointedatsourcesofheator
moving objects, e.g. fluttering curtains.
•CheckthatPIRisnotmountedaboveconvector
heaters or pointing directly at windows.
PIR LED flashes
•Batteriesareloworthetamperswitchisdisturbed.
Check that the tamper switch spring is making
contact with base. If the tamper switch is OK,
change batteries with new alkaline replacements.
PIR does not respond to movement
•Batteriesarecompletelyexhausted.Change
batteries with new alkaline replacements, LED will
flash for 30 seconds while components initialise.
_____________________________________________
Door Contact
Door contact LED lights up
•Batteriesareloworthetamperswitchdisturbed.
Check that the tamper switch spring is making
contact with the mounting surface. If the tamper
switch is OK, change batteries with new CR2032
coin cell replacements.
Door contact does not respond to door
opening when jumper is in test position
•Batteriesarecompletelyexhausted.Change
batteries with new CR2032 coin cell replacements.
•Themagnetistoofarawayfromthedoorcontact.
Check that the gap between door contact and
magnet is not greater than 8mm.
_____________________________________________
Control box’s LED 2 (Warning
LED)
Red ON: Alarm been triggered. Arm and then
disarm the system once more will clear this
LED.
FLASH: Ongoing alarm event
Yellow ON: Device fault (Tamper/Low battery)
FLASH: Mains power failed
OFF: Normal
For online assistance, please visit: www.Yale.co.uk